Model No: AIPL-NDR-240
Applications
• Industrial control system
• Semi-conductor fabrication equipment
• Factory automation
• Electro-mechanical
Features
• Universal AC input / Full range
• Built-in active PFC function
• Protections: Short circuit / Overload / Over voltage/ Over temperature
• Cooling by free air convection
• Can be installed on DlN rail TS-35/7.5 or 15
• UL 508 (industrial control equipment) approved
• EN61000-6-2(EN50082-2) industrial immunity level
• 100% full load burn-in test
• 3 years warranty
Description
AIPL-NDR-240 is one economical slim 240W Din rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 63mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
AIPL-NDR-240 is designed with a metal housing that enhances the unit’s power dissipation. With working efficiency up to 90%, the entire series can operate at the ambient temperature between -20℃ and 70℃ under air convection. lt is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN60950-1, etc.) make AIPL-NDR-240 a very competitive power supply solution for industrial applications.
Model Encoding
SPECIFICATION
MODEL | AIPL-NDR-240-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 10A | |
CURRENT RANGE | 0 – 10A | |
RATED POWER | 240W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ. RANGE | 24 – 28V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 28ms/230VAC 22ms/115VAC at full load | |
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | |
EFFICIENCY (Typ.) | 88.50% | |
AC CURRENT (Typ.) | 2.5A/115VAC 1.3A/230VAC | |
INRUSH CURRENT (Typ.) | 20A/115VAC 35A/230VAC | |
LEAKAGE CURRENT | <1mA/ 240VAC | |
PROTECTION | OVERLOAD | 105 – 130% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||
OVERVOLTAGE | 29 – 33V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL508, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH | |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class A, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | |
OTHERS | MTBF | 230.2K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 63*125.2*113.5mm (W*H*D) | |
PACKING | 1Kg; 12pcs/13Kg/1.1CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation, and load regulation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended. 6. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” |
Note: The information contained in this data sheet is subject to normal manufacturing tolerances. Specifications are subject to change on requirement.
Reviews
There are no reviews yet.