120W Single Output Industrial DIN RAIL AIPL-EDR-120

SKU: AIPL-EDR-120 Category: Tags: , , ,
Model No: AIPL-EDR-120

 

Applications

• Industrial control system
• Semi-conductor fabrication equipment
• Factory automation
• Electro-mechanical

Features

• Universal AC input / Full range
• Built-in active PFC function
• Protections: Short circuit / Overload / Over voltage/ Over temperature
• Cooling by free air convection
• Can be installed on DlN rail TS-35/7.5 or 15
• UL 508 (industrial control equipment) approved
• EN61000-6-2(EN50082-2) industrial immunity level
• 100% full load burn-in test
• 3 years warranty

 

Description

AIPL-EDR-120 is one economical slim 120W Din rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The
body is designed to be 40mm in width, allowing space-saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to
264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
AIPL-EDR-120 is designed with a metal housing that enhances the unit’s power dissipation. With working efficiency up to 88.5%, the entire series
can operate at the ambient temperature between -20℃ and 60℃ under air convection. lt is equipped with constant current mode for over-load
protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control
apparatus (UL508, TUV EN60950-1, etc.) make AIPL-EDR-120 a competitive power supply solution for industrial applications.

 

Model Encoding

AIDL-EDR-120-Encoding

SPECIFICATION
MODEL AIPL-EDR-120-24
OUTPUT DC VOLTAGE 24V
RATED CURRENT 5A
CURRENT RANGE 0 – 5A
RATED POWER 120W
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE 24 – 28V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±1.0%
SETUP, RISE TIME 1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC 10ms/115VAC at full load
INPUT VOLTAGE RANGE Note.6 DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.) 87.50%
AC CURRENT (Typ.) 2.25AI115VAC 1.3A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC 35Al230VAC
LEAKAGE CURRENT <1mA/ 240VAC
PROTECTION OVERLOAD 105 – 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 29 – 33V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT WORKING TEMP. -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
(Note 4)
SAFETY STANDARDS UL508, TUV EN60950-1 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to EN55022 (CISPR22) Class A, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
OTHERS MTBF 474.6K hrs min. MIL-HDBK-217F (25°C)
DIMENSION 40*125.2*113.5mm (W*H*D)
PACKING 0.6Kg; 20pcs/13Kg/1.16CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended.
6. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

 

Reviews

There are no reviews yet.

Be the first to review “120W Single Output Industrial DIN RAIL AIPL-EDR-120”

Your email address will not be published. Required fields are marked *