Model No: AIPL-EDR-120
Applications
• Industrial control system
• Semi-conductor fabrication equipment
• Factory automation
• Electro-mechanical
Features
• Universal AC input / Full range
• Built-in active PFC function
• Protections: Short circuit / Overload / Over voltage/ Over temperature
• Cooling by free air convection
• Can be installed on DlN rail TS-35/7.5 or 15
• UL 508 (industrial control equipment) approved
• EN61000-6-2(EN50082-2) industrial immunity level
• 100% full load burn-in test
• 3 years warranty
Description
AIPL-EDR-120 is one economical slim 120W Din rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The
body is designed to be 40mm in width, allowing space-saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to
264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
AIPL-EDR-120 is designed with a metal housing that enhances the unit’s power dissipation. With working efficiency up to 88.5%, the entire series
can operate at the ambient temperature between -20℃ and 60℃ under air convection. lt is equipped with constant current mode for over-load
protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control
apparatus (UL508, TUV EN60950-1, etc.) make AIPL-EDR-120 a competitive power supply solution for industrial applications.
Model Encoding
SPECIFICATION
MODEL | AIPL-EDR-120-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 5A | |
CURRENT RANGE | 0 – 5A | |
RATED POWER | 120W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | |
VOLTAGE ADJ. RANGE | 24 – 28V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 16ms/230VAC 10ms/115VAC at full load | |
INPUT | VOLTAGE RANGE Note.6 | DC input operation possible by connecting AC/L(+), AC/N(-)] |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | |
EFFICIENCY (Typ.) | 87.50% | |
AC CURRENT (Typ.) | 2.25AI115VAC 1.3A/230VAC | |
INRUSH CURRENT (Typ.) | 20A/115VAC 35Al230VAC | |
LEAKAGE CURRENT | <1mA/ 240VAC | |
PROTECTION | OVERLOAD | 105 – 130% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 29 – 33V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL508, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH | |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class A, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | |
OTHERS | MTBF | 474.6K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 40*125.2*113.5mm (W*H*D) | |
PACKING | 0.6Kg; 20pcs/13Kg/1.16CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation, and load regulation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended. 6. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” |